Product Pictures
Products: LED FloodLights 1-100W
Brand Parameters
(Note: The data is provided by the supplier, please compare with independent testing results by BackMorning.)
Lumen Efficiency: NO MARK
Wattage: 100W
IP Rating: IPX5
Color Temperature(CCT): 6,500K
Beam Angle: NO MARK
UGR: NO MARK
Electric Safety Testing
Insurance Resistance: Pass
Electric Strength: N/A
Ground Resistance: Pass
Spectrum Testing & Electrical Testing
in the beginning
Note: For low voltage LED Light Strips, we test the spectrum data of the 1st meter, and test the power of the whole roll.
LED FloodLights CCT(Color Temperature): 6,232K
Ra: 83.3
CRI: 76
SDCM: 2.8
Power: 97.41W
Power Factor: 0.97
Input Voltage: 219.8V
Spectrum Testing & Electrical Testing
after 30 minutes
Note: For low voltage LED Light Strips, we test the spectrum data of the 1st meter, and test the power of the whole roll.
LED FloodLights CCT(Color Temperature): 6,434K
Ra: 83.9
CRI: 77.1
SDCM: 0.4
Power: 93.61W
Power Factor: 0.97
Input Voltage: 219.8V
Gonio Photometer Testing
(IES testing/ Light Distribution testing/Darkroom testing)
LED FloodLights Total Lumen: 9,812LM
Lumen Efficiency: 103.84LM/W
Beam Angle:113.2°
UGR:NO TEST
IP Testing
Visual Inspection:
Pass
Aging Testing:
Pass
Electric Safety Testing:
Pass
Thermal Testing
(Temperature Grow)
Other Testings
Pull: Fail
Workmanship: Pass
Inspector’s Conclusion:
Testing Result:
Fail
Comments:
The displacement exceeded two millimeters during the pull testing.
Note: Our test results are only applicable to the sample tested, and the results can be influenced by aspects such as the design, material, and craftsmanship of the sample. Therefore, it is entirely possible that the product you purchase may not be consistent with our tested sample. If you wish to procure bulk LED light products of excellent quality, please utilize our inspection services